PATIENT MONITOR
Manufacturer:
SPACETECH HEALTHCARE LIMITED
Model: RESCATE 03
Rescate 03 is simple and touchable model having various latest features.
13.3”-inch-high brightness long life LED display with touch screen.
Iconify key operation, centralized menu make it easier and faster.
Information monitoring design supports bedside devices centralized display.
Key Features
-
NIBP
-
ECG
-
HEART RATE
-
SpO2
-
TEMPERATURE
-
PULSE RATE
-
IBP(Optional)
-
ETCO2 (Optional)
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Measuring and alarm range:
Adult Mode: SYS 20 ~ 270 mmHg,DIA 10 ~ 265 mmHg,MEAN 10 ~ 270 mmHg
Pediatric Mode:SYS 20 ~ 240 mmHg, DIA 10 ~ 190 mmHg,MEAN 10 ~ 235 mmHg
Neonatal Mode:SYS 15 ~140 mmHg,DIA 10 ~125 mmHg,MEAN 10 ~ 135mmHg
Static pressure range: 0mmHg ~ 300mmHg Static pressure accuracy: ±3mmHg
Blood pressure accuracy: maximum average deviation ±5mmHg; Maximum standard
deviation:±8mmHg
Overpressure Protection
Adult Mode 290±3 mmHg
Pediatric Mode 250±3 mmHg
Neonatal Mode 150±3 mmHg
ECG
Lead configuration
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V1- V6
Waveform 3 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
ECG gain
Gain: x0.5mm/mV, x1.0mm/mV, x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto, deviation≤±5%
HEART RATE
HR and Alarm
Range: Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm
Accuracy ± 1% or ± 1bpm, whichever is greater
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
ECG signal range 0.2~8mV
Input Impedance
Differential Input Impedance > 5 MΩ
Bandwidth: Surgery 1 ~ 15 Hz,Monitor 0.5 ~ 35 Hz, Diagnostic 0.05 ~ 100 Hz
common mode rejection ratio (CMRR)
CMRR: Monitor > 105 dB, Operation > 105 dB, Diagnosis > 85 dB
Electrode polarization voltage range
Electrode offset potential 300mV
pace pulse detection
can detect pacing pulses meet the following conditions:
Amplitude:1 mV ~ 10mV;width:0.5ms ~ 2ms;rise time:10us~100μs
Pacing pulse suppression
When the pacing analysis switch is turned on, pacing pulses meeting the following
conditions can be suppressed, without affecting the heart rate calculation: Amplitude
:±2 mV ~ ±700mV;width:0.1ms ~ 2ms;rise time:10us ~ 100μs
Baseline recovery time
Baseline Recovery < 3 S After Defi.
Calibration Signal
Calibration Signal 1 (mV p-p), Accuracy :±5%
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% ±2 % , 0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
PULSE RATE
Measuring and Alarm Range 20~300bpm
Resolution 1bpm
Accuracy ±1bpm
TEMPERATURE
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec
IBP(Optional)
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range:
ART 0 ~ 300 mmHg,
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg ,
P1/P2 -10 ~ 300 mmHg
Press Sensor:
Sensitivity 5 uV/V/mmHg,
Impedance 300-3000Ω
zero calibration adjustment range 200mmHg
excitation voltage 5VDC, ±2%
Resolution 1 mmHg
Accuracy ±2% or ±1mmHg, which great
Actualization interval about 1 Sec
ETCO2 (Optional)
Measuring alarm range 0% ~ 20%
Resolution 1 mmHg
Accuracy 2 mmHg @ < 5.0% CO₂ (at ATPS)
Respiratory rate range 3 - 150 bpm
ALARM
Alarm level:high、medium、low,
Alarm type:Physiological alarm, technical alarm,latch and unlatch available.
Alarm indicator:Red and yellow dual color alarm indicator light
Monitor type (according to GB9706.1)
Standard electrical shock resistance class I
EMC grade grade A
the degree of protection against electric shock ECG (RESP)is type CF;
SpO2、NIBP、TEMP is type BF;
Waterproof type IPX1.
Working mode continuous working mode
WORKING ENVIORNMENT
Temperature:
Working 5℃~40℃
Transportation and storage (-20 ~ +55) C
Humidity:
Working 15%~80 % (non-condensing)
Transportation and storage ≤93% (non-condensing)
Altitude:
Working (-500 - 4,600) m (-1,600 - 15,000)inch
Transportation and storage (-500 - 13,100)m (-1,600 - 43,000)inch
Electrical specifications:
A.C 100V-a.c.240V,50Hz/60Hz, input power 40VA
Fuse: T1.6AL 250V d.c.15V/2A(7—15V)
DISPLAY INFORMATION
Color LCD touch screen
13.3(1366*768pixel),15.6(1366*768pixel)。
Up to 8 waveform display,1 alarm indicator (yellow/red).
1 battery charging status indicator (green),,1 AC power status indicator
Three sound alarm modes corresponding to the alarm state
BATTERY
14.8V/2200mAh or 7.4V/4800mAhq Li-ion battery
Can work over 150min on battery
After the first low power alarm, can continue to work for about 10 minutes. After 15 minutes,
it will shut down automatically.
The maximum charging time for 14.8V battery is no more than 3 hours, and the maximum charging
time for 7.4V battery is no more than 5 hours.
RECORDER (OPTIONAL)
width 80mm; speed 25 mm/S
waveform 3; record type 8s、16sreal time record
Central Monitoring
Multi-channel central station for 12 bedside monitors and extendable
Capability to attach dual displays
Operating system should be windows
24-inch central station monitor display
Resolution minimum 1920 * 1080
Laser printer
750 + arrhythmia episodes can be saved
70000+ ST recall files data can be stored
120 hours’ trend data can be stored
Up to 30 parameters
Freeze waveform
All parameter alarms on central station monitor with bed no. identification
All alarm of each bedside monitors selectable from central work station
Full disclosure
Keyboard and mouse
Graphical and tabular
Arrhythmia analysis feature
Ability to attach with imported sine wave ups.
OEM Warranty Certified
Turnkey Installation
24/7 Biomedical Support