Manufacturer: SPACETECH HEALTHCARE LIMITED Model: SPLIT MAX

15” TFT LCD touch screen, displays the ventilation parameters, Alarm information, and Oscillogram. High sensitivity touch screen ensures accurate and easy operations. Alternate button of dual control. The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Depart- ment and other departments. Professional design for adult, child and infant inhalation anesthesia and respiratory management, with advanced ventilation modes. Outstanding ergonomic design, it ranks high level in safty, stability and convenience as well as user experiences. SPLIT MAX high-end model combine proven ventilation technology with the latest refinements in ergonomics and systems integration with an advanced, easy to use anesthesia table designed together with experienced experts to streamline your anesthesia workflow

Key Features

  • Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
  • Safty design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
  • Alarm: 3 level alarm system, visual and sound alarm information.
  • Power: Built-in battery ensure 2-3 hours using when power failure.
  • Separate design of electric circuit and gas circuit ensure long using life.
  • Flexible configurations able to customize your requirements.
  • Altitude compensation: Suitable for high/low altitude areas.
  • Vaporizer:
  • Accurately delivers a calibrated flow, Halothane, Enflurane, Isoflurane, Sevoflurane for choice. Suitable for low flow anesthesia. (Two Options for Mounting).
  • Breathing circuit:
  • Integrated breathing circuit design. Breathing tube resistants high temperature sterilization. Ensure easy operating and keep tidy.
  • LED top light
  • Convenient for endoscopy operation.
  • Pressure gauge
  • Real time pressure for Air, O2, N20 from central gassupply and gas cylinders.
  • ACGO and fast oxygen supply (Optional)
  • Emergency situation and revival after operation.
  • Handle
  • Easy and safety transport.
  • Drawer
  • 2 drawers with large capacity for storing accessories.
  • Pedal
  • User-friendly design convenient for doctors to relax foot.
  • Central brake is optional.
  • Caster
  • Diameter: 125mm,
  • 2 individual brakes of 4 casters.
  • Bellow
  • Integrated bellow 0mL-1500mL.
  • Suitable for all range patients.
  • APL valve
  • Automatic decompression to ensure safety.
  • ETCO2 (Optional)
  • End-tidal carbon dioxide concentration monitoring, real-time understanding of the patient state.
Ventilation mode:
IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH, MANUAL
Ventilator Parameter Range:
Flowmeter O2(0.2 - 15 L/min)
N20 (0.2 ~ 12 L/min)
AIR (0.2 ~ 15 L/min)
Rapid oxygen supply 25 L/min ~ 75 L/min
Tidal volume(Vt) 0,20 mL ~ 1500 mL
Frequence (Freq) 1/min ~ 100/min
I:E VTH 4:1 ~ 1:8, VTL 2:1 ~ 1:8
PEEP 0 cmH20 ~ 30 cmH2O
Pressure triggering sensitivity (PTr) -20 cmH20 ~ 0 cmH2O (Based on PEEP)
Flow trigger sensitivity (FTr) OFF, 0.5 L/min ~ 30 L/min
Pressure control (PC) 5 cmH20 ~ 70 cmH2O
SIGH 0 (off) 1/100 ~ 5/100
Apnea ventilation OFF, 5% ~ 60%s
Pressure limit 10 cmH20 ~ 100 cmH20
Monitoring Parameter:
Frequence (Freq) 0/min ~ 120/min
Tidal volume (Vt) 0 mL ~ 3000 Ml
MV 0 L/min ~ 100 L/min
Oxygen concentration 15 % - 100 %
Alarm & Protection:
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm < 10.2 ÷ 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19 % ~ 100 %
Low oxygen concentration alarm 18% - 99 %
High airway pressure alarm 20 cmH20 - 100 cmH20
Low airway pressure alarm 0 cmН20 ~ 20 сmН20
High minute volume alarm Adult (5 L/min ~ 20 L/min)
Low minute volume alarm Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min)
Continuous pressure alarm (PEEP+1,5 kPa) over 16 s
Suffocation warning 5s ~ 60 s no spontaneous ventilation
The maximum limited pressure ≤12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Working Condition:
Gas source 02, N20, AIR
Pressure 280 kPa ~ 600 kPa
Voltage 100 ~ 240 V
Power frequency 50/60 Hz
Oscillogram:
P-T (pressure-time)
F-T (fiflow-time)
ETCO2 - T (ECTO2 – Time)
V-T (volume-time)
P-V loop (pressure-volume loop)
P-F loop (pressure-flflow loop)
F-V loop (fiflow-volume loop)
OEM Warranty Certified Turnkey Installation 24/7 Biomedical Support
Innotech Live Desk

Need assistance? Chat with our biomedical team live!

Innotech Live Desk
Biomedical Support • Online
Welcome to Innotech Medical

Please enter your details to start a live conversation with our biomedical team.

Innotech Assistant is typing