logo

Our mission is to ensure the generation of accurate and precise findings.

Contact Us 1st Floor, Plot: A-301, Sardar Ali Sabri Road, Block-2, Gulshan e Iqbal, Karachi, Sindh, Pakistan. +92 331 6699992 info@innotechmed.com
Get Update
Thank you!
You have successfully subscribed to Innotech updates.
ANESTHESIA MACHINE Click to enlarge

ANESTHESIA MACHINE


Manufacturer: SPACETECH HEALTHCARE LIMITED Model: SPLIT PLUS

SPLIT PLUS high-end model combine proven ventilation technology with the latest refinements in ergonomics and systems integration with an advanced, easy to use anesthesia table designed together with experienced experts to streamline your anesthesia workflow.

Key Features

  • Trust Point:
  • Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
  • Safty design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
  • Alarm: 3 level alarm system, visual and sound alarm information.
  • Power: Built-in battery ensure 2-3 hours using when power failure.
  • Separate design of electric circuit and gas circuit ensure long using life.
  • Flexible configurations able to customize your requirements.
  • Altitude compensation: Suitable for high/low altitude areas.
Ventilation mode:
IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH, MANUAL
Ventilator Parameter Range:
Flowmeter 02(0.1 - 10 L/min)
N20 (0.1 ~ 10 L/min)
AIR (0.1 ~ 10 L/min)
Rapid oxygen supply 25 L/min ~ 75 L/min
Tidal volume(Vt) 0,20 mL ~ 1500 mL
Frequence (Freq) 1/min ~ 100/min
I:E VTH 4:1 ~ 1:8, VTL 2:1 ~ 1:8
PEEP 0 cmH20 ~ 30 cmH2O
Pressure triggering sensitivity (PTr) -20 cmH20 ~ 0 cmH2O (Based on PEEP)
Flow trigger sensitivity (FTr) OFF, 0.5 L/min ~ 30 L/min
Pressure control (PC) 5 cmH20 ~ 70 cmH2O
SIGH 0 (off) 1/100 ~ 5/100
Apnea ventilation OFF, 5% ~ 60%s
Pressure limit 10 cmH20 ~ 100 cmH20
Monitoring Parameter:
Frequence (Freq) 0/min ~ 120/min
Tidal volume (Vt) 0 mL ~ 3000 Ml
MV 0 L/min ~ 100 L/min
Oxygen concentration 15 % - 100 %
Alarm & Protection:
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm < 10.2 ÷ 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19 % ~ 100 %
Low oxygen concentration alarm 18% - 99 %
High airway pressure alarm 20 cmH20 - 100 cmH20
Low airway pressure alarm 0 cmН20 ~ 20 сmН20
High minute volume alarm Adult (5 L/min ~ 20 L/min)
Low minute volume alarm Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min)
Continuous pressure alarm (PEEP+1,5 kPa) over 16 s
Suffocation warning 5s ~ 60 s no spontaneous ventilation
The maximum limited pressure ≤12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Working Condition:
Gas source 02, N20, AIR
Pressure 280 kPa ~ 600 kPa
Voltage 100 ~ 240 V
Power frequency 50/60 Hz
Oscillogram:
P-T (pressure-time)
F-T (fiflow-time)
ETCO2 - T (ECTO2 – Time)
V-T (volume-time)
P-V loop (pressure-volume loop)
P-F loop (pressure-flflow loop)
F-V loop (fiflow-volume loop)
OEM Warranty Certified Turnkey Installation 24/7 Biomedical Support
Innotech Live Desk

Need assistance? Chat with our biomedical team live!

Innotech Live Desk
Biomedical Support • Online
Welcome to Innotech Medical

Please enter your details to start a live conversation with our biomedical team.

Innotech Assistant is typing